Dynamic Reactive Compensation Unit — AI-powered power grid monitoring, real-time analytics, and automated reactive compensation for modern distribution networks.
Built to withstand harsh environments while delivering precise, real-time control.
| Operating Voltage | 110V - 240V AC, 50/60Hz (Standard) |
|---|---|
| Control Outputs | Up to 12 Programmable Relay Contacts (Expandable) |
| Communication Protocols | 4G/5G/Wifi |
| Measurement Accuracy | Class 0.2s for Voltage/Current, Class 0.5s for Power/Energy |
| Operating Temperature | -20°C to +70°C (Industrial Grade) |
| Enclosure Rating | IP65 Rated (Dust-tight and water jet resistant) |
Experience your power grid in three dimensions. Our AI-driven Digital Twin continuously learns from live grid data to autonomously predict failures and optimize reactive power compensation before anomalies occur.
Machine learning algorithms detect microscopic harmonic distortions, predicting capacitor wear weeks before critical failure.
The neural network continuously fine-tunes switching sequences to minimize contactor wear and maximize power factor.
Visualize energy flows, thermal stress levels, and active compensation states via a highly responsive 3D interface.
From real-time monitoring to AI-driven predictive analytics, DelSmart DRCU delivers complete visibility and control over your distribution network.
Real-time voltage, current, active & reactive power monitoring across all three phases with harmonic spectrum analysis.
AI-powered health index scoring, thermal stress analysis, voltage stress monitoring, and predictive fault detection.
Automatic capacitor bank switching with LCD-style digital twin display showing PF, mode, stages, and alarm status.
Import/export energy tracking, cumulative consumption analysis, maximum demand forecasting, and loss cost monitoring.
Random Forest & LightGBM models for demand forecasting, anomaly detection via Isolation Forest, and capacitor failure prediction.
Real-time system alerts, capacitor stage failure tracking, sag/swell detection, THD monitoring, and severity-based notifications.
Set up your DRCU, connect your assets, and let AI-driven automation handle the rest.
Register transformers, feeders, substations, and devices. Configure SCADA connections and data sources.
Real-time dashboards with 12+ charts, KPI cards, and AI insights. Track health, power quality, and demand metrics.
AI recommends capacitor switching actions. APFC controller auto-executes. Predict faults before they happen.
Generate energy reports, export data, and take data-driven decisions with full audit trail and SMS authorization.
Moving beyond basic monitoring to deliver measurable ROI through predictive maintenance and automated power quality correction.
DelSmart DRCU minimizes unplanned downtime and optimizes grid efficiency, saving thousands in operational and penalty costs every year.
Automated reactive compensation maintains PF at target levels, completely removing utility penalties.
AI predicts transformer degradation and thermal stress weeks before a catastrophic burnout occurs.
With real-time digital twins and remote SCADA control, dispatch teams only when genuinely needed.
The DelSmart DRCU dashboard puts everything you need in one place — real-time metrics, predictive insights, and actionable intelligence.
The intelligent operations dashboard consolidates power quality metrics, demand forecasting, asset health scores, and APFC control into a unified dark-mode interface optimized for control room operators.
DelSmart DRCU covers the full spectrum of distribution grid management from substation-level monitoring to field device control.
Voltage, current, power factor, and demand tracking per transformer and feeder
Import/export kWh, kVAh, kVARh tracking with cumulative and interval analysis
THD monitoring, voltage unbalance, current unbalance, and frequency analysis
12-stage capacitor bank control with auto/manual mode, PF targeting, and Q-learning optimization
24-hour load prediction using LightGBM regression with confidence intervals
Isolation Forest algorithm for detecting voltage sag/swell, overvoltage, and device anomalies
Designed for scale and resilience, our control units adapt to the unique power demands of diverse industrial environments.
Stabilize voltage sags during heavy motor starts and prevent harmonic distortion from VFDs from damaging sensitive equipment.
Optimize HVAC power consumption and maintain perfect power factor across large IT parks and shopping malls to eliminate utility penalties.
Provides grid operators with real-time SCADA integration, dynamic reactive compensation, and predictive transformer maintenance.
Most of our industrial clients recover the cost of the DelSmart DRCU deployment within the first 4 to 6 months through eliminated utility penalties and energy savings.
PF Penalties Eliminated
Avg. Demand Reduction
Average Payback Period
Your grid telemetry and control systems are protected by end-to-end encryption, strict access controls, and immutable audit logs.
All telemetry sent from the DRCU to the cloud is encrypted using TLS 1.3. Device credentials are authenticated via secure MQTT brokers.
Granular permissions ensure that only authorized engineers can trigger remote switching or modify capacitor staging configurations.
The unit continues executing intelligent APFC algorithms and safety interlocks locally even if external network connections are completely severed.
Everything you need to know about implementing DelSmart DRCU in your facility.
Yes. The DelSmart DRCU supports standard industrial protocols including Modbus RTU/TCP, DNP3, and IEC 61850, allowing seamless integration with your existing SCADA and BMS platforms.
The system uses edge-computing combined with cloud models (Random Forest, Isolation Forest) to analyze historical power quality data, identifying microscopic anomalies that indicate impending capacitor or transformer failure.
Absolutely. The built-in APFC controller features 12 programmable relay outputs that can drive standard contactors or thyristor switches regardless of the original capacitor bank manufacturer.
The DRCU operates autonomously. All automated switching, safety interlocks, and local data logging continue to function perfectly offline. Data is synced to the cloud once the connection is restored.
Our intelligent nodes are actively monitoring and optimizing grid health around the clock.
Data Points
Processed Every DaySubstations
Actively MonitoredUptime
Cloud Telemetry GuaranteeSaved
In Utility Penalties AnnuallyDelSmart IoT is dedicated to building intelligent, autonomous hardware and software solutions for the modern power distribution network. Our engineering teams combine decades of experience in power electronics with cutting-edge AI software development.
By bringing IoT capabilities to legacy infrastructure, we help utilities and large industries achieve better energy efficiency, reduced carbon footprints, and complete operational transparency.
III Cross, 53-2, MKP Colony Main St, Maniyakarampalayam,
Ganapathy, Coimbatore, Tamil Nadu 641006
098949 95423
Pioneering Smart Grid Technologies & Industrial Automation
DelSmart DRCU connects to our low-latency cloud infrastructure, processing millions of grid events per second to ensure your distribution network operates flawlessly.
Uptime SLA
Scalable Nodes
Cloud Latency
Join operators who rely on DelSmart DRCU for intelligent, automated power distribution control.
Get Started Now